PERFORMANCE SPECIFICATION With Optimum Load Resistance
Accuracy
0.2% (Standard)
Repeatability
0.1% Full Scale
Response Time
150 Milliseconds Maximum
Temperature Range
-25 deg. C to 85 deg. C
Temperature Coefficient
0.04% F.S./ deg. C
Conductor Cable Voltage
5000 Volts (Insulated Cable)
Supply Voltage
5 to 40 V.D.C.
Signal Out
4 to 20 mA
Frequency Nominal
50 / 60 Hz
CONNECTION SPECIFICATION
Conductor Cable Size
Up To 0.25"dia
Wire Range -
Top Terminal
14 to 22 AWG
Dielectric Withstand
16 KV / mm
CHARACTERISTIC CURVE
OPTIMUM LOAD RESISTANCE
The optimum load resistance is actually the sum of the line resistance, receiver
resistances and added external load resistance. However, in many applications, the line resistance and receiver resistances are negligible in comparison to the added external load resistance. The following equation may apply:
RL = ( VS - 5 ) X 40 Where:
RL = Load Resistance in Ohms.
VS = Supply Voltage in Volts D.C.
Manufacturer maintains right to change specifications without notice; prices as of January 1, 2008.